How to Install and Use of Electric Well Water Pump?

electric well water pump

Electric well Water pump is a kind of electric water pump which are divided into DC water pump and AC water pump. DC water pumps are widely used in home appliances, bathrooms, automotive water cooling systems and other places powered by DC power, while AC electric water pumps are used in AC power applications.

automotive electric water pump vp90a
Electric water pump

People can install electric well water pumps on hand-pressure water wells (commonly known as foreign wells) to replace hand-pressure water pumping. When there is a power outage or a small amount of water is used, hand pressure water pumping is still used. You can also install Electric water pumps in earthen wells, ponds, and rivers to pump water. It is suitable for small gardens and small nurseries, as well as rural “two-household” flour mills, tofu mills, wineries, and pig and chicken farms. Farmers who have 220-volt AC lighting electricity can install this single-phase electric water pump. Take B03 and B05 water pumps as examples for introduction as follows:

1. Remove the Wellhead of the Hand-Operated Water Well

When installing, first remove the wellhead of the hand-operated water well, connect the three-way pipe to the well pipe, connect the upper outlet to the wellhead, and connect the horizontal outlet to the water pump (see the schematic diagram). During the installation process, we should seal the pipe joints well, and there must be no air leakage, otherwise it will affect the pumping volume or even fail to pump water.

2. Water diversion and exhaust

You should divert the hand-operated water well to fill the well pipe with water, and then fill it with water from the water outlet of the water pump to remove the air in the pump. Only then you can start the motor.

3. Start

Turn the switch clockwise to the “start” position (this position cannot be kept for more than 3 seconds, otherwise it is easy to burn the motor), and then immediately turn it clockwise to the “open” position to operate normally.

4. Stop

Turn the switch clockwise to the “stop” position to stop the motor immediately. If you need to remove the water pump, you should first turn off the power. After removing the water pump, pour out the water in the pump body and store it in a dry place. The three-way pipe on the hand-operated well should be covered with a cap.

5. Earth well installation

Erect a nylon pipe or iron pipe from the well edge to the well, and install a check valve at the lower end of the pipe to prevent the water in the water pump and the pipe from flowing back. So that it is easy to fill water and exhaust air into the pump, and water can be sucked up quickly when starting.

Storage

After electric well water pump is out of service, we should remove the water pump and rubber hose from the well. After draining the water, check the wear degree of the water pump impeller, bearings, cups and other parts. Replace the parts if pump with serious damage. Clean the bearings with gasoline, apply butter, and install them properly. Remove the rust on the iron castings such as the bottom valve and elbow of the water pump with a wire brush and apply butter. Also we should start it every 7 to 10 days, usually after about 30 minutes, to prevent the rotating parts from rusting. If it is out of service for a long time, you should extract the electric well water pump from the well, inspect and storage it in the warehouse.

Facebook
Twitter
LinkedIn
Pinterest

Leave a Reply

Your email address will not be published. Required fields are marked *

Filter pumps by Parameters

PRODUCT CATEGORY

FEATURED PRODUCTS

VP90A Pump Main Parameters
Rated Voltage 24V
Max Head 24Meters, 25Meters
Max Flow 100L/Min, 110L/Min
Inlet Diameter Φ38mm
Outlet Diameter Φ38mm
Dimensions 183x103x240mm
Noise ~60dB
Liquid Temperature -40~125 Celsius
VP90E Pump Main Parameters
Rated Voltage 24V
Max Head 45 Meters
Max Flow 100L/Min
Inlet Diameter Φ38mm
Outlet Diameter Φ38mm
Dimensions 175x100x170mm
Noise ~60dB
Liquid Temperature -40~125 Celsius
VP90D Main Parameters
Rated Voltage 24V
Max Head 18M
Max Flow 280L/Min
Inlet Diameter Φ38mm
Outlet Diameter Φ38mm
Dimensions 188.1x100x176.9mm
Noise ~60dB
Liquid Temperature -40~125 Celsius
VP80E Main Parameters
Rated Voltage 13.5V, 24V
Max Head 14M
Max Flow 55L/Min
Inlet Diameter Φ20mm
Outlet Diameter Φ20mm
Dimensions 131x112x80mm
Noise ~48dB
Liquid Temperature -40~125 Celsius
VP62E Main Parameters
Rated Voltage 12V
Max Head 9M
Max Flow 35L/Min
Inlet Diameter Φ20mm
Outlet Diameter Φ20mm
Dimensions 134*120*80mm
Noise ~40dB
Liquid Temperature -40~125 Celsius
VP50R Main Parameters
Rated Voltage 12V
Max Head 4.5M
Max Flow 30L/Min
Inlet Diameter Φ20mm
Outlet Diameter Φ20mm
Dimensions 96.3*84.7*48mm
Noise ~40dB
Liquid Temperature -40~125 Celsius
VP100A Main Parameters
Rated Voltage 220V
Max Head 38M, 48M
Max Flow 100L/Min,100L/Min
Inlet Diameter Φ20mm
Outlet Diameter Φ20mm
Dimensions 223.4×126.0x178.0mm
Noise ~50dB
Liquid Temperature -30~70 Celsius
VP30A Pump Main Parameters
Rated Voltage 6V, 12V
Max Head 1.5 Meters, 3 Meters
Max Flow 2.5L/Min, 4L/Min
Inlet Diameter Φ8mm
Outlet Diameter Φ8mm
Dimensions 53.5x40x34mm
Noise ~30dB
Liquid Temperature -25~50 Celsius
VP40H Pump Main Parameters
Rated Voltage 12V, 24V, 24V
Max Head 8Meters, 13 Meters, 15 Meters
Max Flow 10L/Min, 12L/Min, 13L/Min
Inlet Diameter Φ18mm
Outlet Diameter Φ9.8mm
Dimensions 82.45×48.0x67.6mm
Noise ~40dB
Liquid Temperature -25~80 Celsius
VP40S Main Parameters
Rated Voltage 12V, 24V
Max Head 3M, 8M
Max Flow 8L/Min, 13L/Min
Inlet Diameter Φ20mm
Outlet Diameter Φ20mm
Dimensions 82.3x102x46.4mm
Noise ~40dB
Liquid Temperature -40~110 Celsius
VP40T Pump Main Parameters
Rated Voltage 12V, 24V, 24V
Max Head 8Meters, 13 Meters, 15 Meters
Max Flow 10L/Min, 12L/Min, 13L/Min
Inlet Diameter Φ20mm (1/2 inch thread)
Outlet Diameter Φ20mm (1/2 inch thread)
Dimensions 83.4x48x69.7mm
Noise ~40dB
Liquid Temperature -25~80 Celsius
VP50E Main Parameters
Rated Voltage 12V, 24V
Max Head 8M, 15M
Max Flow 20L/Min, 25L/Min
Inlet Diameter Φ20mm (1/2 inch thread)
Outlet Diameter Φ20mm (1/2 inch thread)
Dimensions 96.9x73x84.3mm
Noise ~40dB
Liquid Temperature -20~100 Celsius
VP60A Main Parameters
Rated Voltage 12V, 24V,24V,24V
Max Head 11M, 20M, 25M, 32M
Max Flow 20L/Min, 24L/Min, 25L/Min, 26L/Min
Inlet Diameter Φ20.3mm
Outlet Diameter Φ11.3mm
Dimensions 90.9x60x85.85mm
Noise ~40dB
Liquid Temperature -25~80 Celsius
VP60P Main Parameters
Rated Voltage 12V, 24V,24V,24V
Max Head 11M, 20M, 25M, 32M
Max Flow 20L/Min, 24L/Min, 25L/Min, 26L/Min
Inlet Diameter Φ20mm (1/2 inch thread)
Outlet Diameter Φ20mm (1/2 inch thread)
Dimensions 90.9x60x85.85mm
Noise ~40dB
Liquid Temperature -25~80 Celsius
VP60N Main Parameters
Rated Voltage 12V, 24V
Max Head 11M, 16M
Max Flow 20L/Min, 32L/Min
Inlet Diameter Φ20mm (1/2 inch thread)
Outlet Diameter Φ20mm (1/2 inch thread)
Dimensions 92.5x60x108mm
Noise ~40dB
Liquid Temperature -25~80 Celsius